Home > Error Code > The Data Access Service Is Either Not Running Or Not Yet Initialized Service Manager 2012

The Data Access Service Is Either Not Running Or Not Yet Initialized Service Manager 2012

Contents

Like Show 0 Likes(0) Actions Go to original post Actions Remove from profile Feature on your profile More Like This Retrieving data ... © 2007-2016 Jive Software | Powered by Home March 22, 2013 at 4:15 pm #111866 JamesParticipant Sorry i thought i could copy and paste images, so here's the attachment. I was able to install the secondary Admin Server and promote it RMS. Critical information. http://softbb.net/error-code/sharp-service-code-h4-00.html

Recommend Us Quick Tip Connect to EventID.Net directly from the Microsoft Event Viewer!Instructions Customer services Contact usSupportTerms of Use Help & FAQ Sales FAQEventID.Net FAQ Advertise with us Articles Managing logsRecommended Attachments:You must be logged in to view attached files. This way, if we have complete list, we can avoid this error in future.Watch SQL in Sixty Seconds video to Resolve Connection Error: Reference: Pinal Dave (http://blog.SQLAuthority.com) Tags: SQL Error Messages1Related Just trying to install a standalone root management server SCOM 2012 with a new Management Group. https://social.technet.microsoft.com/Forums/systemcenter/en-US/731a1f20-c914-4e45-b9c1-c8095b97b79f/scom-2012-issue-error-when-starting-scom-management-console-can-you-help-please?forum=operationsmanagergeneral

The Data Access Service Is Either Not Running Or Not Yet Initialized Service Manager 2012

Therefore, all of a sudden a system/database that worked fine on a Windows 2008 Server fails to accept connections from remote machines when upgraded to run on Windows 2008 R2 Server.Reply Is it normal that I can't connect to the Management Group with the upgraded server? I will try the upgrade checklist. Please type your message and try again. 6 Replies Latest reply on Apr 2, 2014 5:44 PM by wwarren SCOM agents can't communicate after weekly patch ssiops Mar 31, 2014 11:12

Check the event log for more information. TCP error code 10061: No connection could be made because the target machine actively refused it 172.16.2.103:5724. [15:40:20]:    Info:    :Info: Waiting 30 seconds before trying to connect to local SDK [15:40:56]:   Do you have group polices that restrict membership of the local administrators group? I thought by starting the new console, I would be update to upgrade all the agents before upgrading the RMS.

InnerException Details: Could not connect to net.tcp://scomms02.ptv.com:5724/DispatcherService. ShareThis! TCP error code 10061: No connection could be made because the target machine actively refused it 10.10.1.185:5724. ---> System.Net.Sockets.SocketException: No connection could be made because the target machine actively refused it Discover More TCP error code 10061: No connection could be made because the target machine actively refused it 172.16.2.103:5724. [15:40:09]:    Info:    :Info: Waiting 5 seconds before trying to connect to local SDK [15:40:20]:  

Document information More support for: Tivoli Netcool/OMNIbus Software version: 7.4.0, 8.1.0 Operating system(s): AIX, HP-UX, Linux, Solaris, Windows Software edition: All Editions Reference #: 1681271 Modified date: 13 May 2016 Site I have started to make my routine to check firewall first before I move to next action item in my troubleshooting list.When I sent this detail to my internal technical list Subscribe to our monthly newsletter for tech news and trends Membership How it Works Gigs Live Careers Plans and Pricing For Business Become an Expert Resource Center About Us Who We I have SQL 2012 Standard installed on one server called SQL01, running Server 2008 R2 Datacentre 64-bit There are 3 instances on there, one default and two named instances.

Sdk Service

I then run the SCOM2012 Upgrade to that server and when it asked for the credential of the Action account and SDK account, it was not able to validate thos account http://blog.sqlauthority.com/2010/10/20/sql-server-could-not-connect-to-tcp-error-code-10061-no-connection-could-be-made-because-the-target-machine-actively-refused-it/ Please turn JavaScript back on and reload this page. The Data Access Service Is Either Not Running Or Not Yet Initialized Service Manager 2012 Re: SCOM agents can't communicate after weekly patch ssiops Apr 1, 2014 10:12 AM (in response to ssiops) We've tried a couple different work arounds but neither succeeded:Workaround 1Enable ScriptScan in Tcp Error Code 10061: No Connection Could Be Made Because The Target Machine Actively Refused It Do you think this could possibly be a permission issue?

The connection attempt lasted for a time span of 00:00:01.9955952. navigate here April 5, 2013 at 2:21 pm #112304 mmats123Participant You missed the switch for EndUser license Agreement /AcceptEnduserLicenseAgreement=1 Author Posts Viewing 15 posts - 1 through 15 (of 19 total) 1 If so, please temporarily uninstalled it to have a check. Re: SCOM agents can't communicate after weekly patch ssiops Apr 2, 2014 5:12 PM (in response to ssiops) So I've read on other sites there might be a sDAT that can

TCP error code 10061: No connection could be made because the target machine actively refused it 172.16.2.103:5724. [15:40:56]:    Info:    :Info: Waiting 60 seconds before trying to connect to local SDK [15:42:02]:   This was just for installation then I could work fine on just 1433. Join & Ask a Question Need Help in Real-Time? http://softbb.net/error-code/call-service-center-sc899.html Watson Product Search Search None of the above, continue with my search SCOM 2012 Probe - Failed to connect to SCOM actively refused; disconnect; disconnecting Technote (troubleshooting) Problem(Abstract) SCOM 2012 probe

The error we keep getting is:The OpsMgrConnector cound not connect to (SERVERNAME):5723. The connection attempt lasted for a time span of 00:00:02.0033530. Before the update, on the previous RMS that now act as a secondary MS, I was able to connect to the Management Group and see the alerts and administer Operation Manager.

InnerException Details: Could not connect to net.tcp://scomms02.ptv.com:5724/DispatcherService.

From APP13 using management studio, I can only connect to the default instance using SQL01 I can connect to the named instances also, but only using the IP address of SQL01, This is a fatal item. For installation I needed more than just 1433 open. April 5, 2013 at 1:56 pm #112300 JamesParticipant I've created a new DASAccount as the first MS was installed with local system etc and have assigned that the relevant permissions.

We are running Windows Server 2008 R2 Enterprise x64 Edition SP1 on our servers and System Center Operations Manager 2007 R2. Adding a registry key (per a Microsoft KB) Here is the message from SCOM Date: 6/27/2012 8:48:49 AM Application: Operations Manager Application Version: 7.0.8443.0 Severity: Error Message: Failed to connect to Error Message while connecting to SDK: The Data Access service is either not running or not yet initialized. this contact form InnerException Details: Could not connect to net.tcp://scomms02.ptv.com:5724/DispatcherService.

Comments: EventID.Net From a Microsoft support forum: "The "OpsMgr Connector" error 21006 may occur if SCE Agent communication port does not open or related two SCE certificates are not correctly installed Nove May 30, 2015 2:37 amI still get error 10061, even after seeing the video and adjusting the procedure accordingly. No Comments Post a comment or leave a trackback: Trackback URL. « Move a snap-shot of OpsManager to anotherdomain How to solve empty ENU display names of user roles in Operations What if you have an ad integrated SCOM agent, that has received the AD policy correctly but still tries to connect to the old management server?

Attachments:You must be logged in to view attached files. I will look at the SQL database. The server was not found or was not accessible. Also, if it is, did you follow the procedures detailed here?

Re: SCOM agents can't communicate after weekly patch ssiops Apr 1, 2014 12:15 PM (in response to k3tg) OK moved to Business. If Microsoft Proxy Server 2.0 Client Software has been installed. How can this happen? You can follow any responses to this entry through the RSS 2.0 feed.